Technical data and characteristics

14

The technical data and characteristics for the 1FW6 Built-in torque motors are specified in this Chapter. This data collection provides the motor data required for configuration and contains a number of additional data for more detailed calculations for detailed analyses and problem analyses. Technical data subject to change.

Note

System-specific data refer to the combination of 1FW6 Built-in torque motors with

SIMODRIVE 611 digital/universal drive systems.

Unless otherwise specified, the following general conditions apply here:

The DC link voltage UZK is 600 V, while the converter output voltage Uamax is 425 V.

The motor is water-cooled with the recommended minimum flow rate according to the data sheet and a water intake temperature TVORL of 35 °C

The rated temperature of the motor winding TN is 130 °C

Voltages and currents are specified as rms values.

Installation altitude of the motors up to 4000 m above sea level.

The performance data for motors with integrated cooling has been determined using a cooling connection adapter

14.1Explanations of the formula abbreviations

Content of the data sheet

The data specified on the data sheets is explained in the following section. It is categorized as follows:

Boundary conditions

Rated data

Limit data

Physical constants

Data for the motor cooler

1FW6 Built-in torque motors

197

Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7

Page 197
Image 197
Siemens 611 Technical data and characteristics, Explanations of the formula abbreviations, Content of the data sheet