Interfaces 8.2 Electrical connections
The cables for the power connection are brought out at the front of the stator (B side). The open cable ends must be connected in a terminal box, which must be provided by the machine manufacturer. Sufficient installation space must be provided in the axes construction. Standard
8.2.1 | Power connection |
| |
Connection assignment |
| ||
|
| Table 8- 4 Power connection for torque motor |
|
|
|
|
|
|
| Converter | Torque motor/stator |
|
| U2 | U |
|
| V2 | V |
|
| W2 | W |
For information on the power connection, refer also to the system integration images contained in the chapter titled "System requirements". The rotor turns clockwise if the torque motor is connected in phase sequence U, V, W. Also refer to "Direction of rotation" in Chapter "Technical features".
8.2.2Signal connection
No direct connection of the temperature monitoring circuits!
DANGER
The temperature monitoring circuits represent a risk of electrical shock!
A direct connection of the temperature monitoring circuits
Temperature sensor connection via SME9x
A connector is used to connect the signal cable to the SME9x (Sensor Module External), whose output is connected at the converter. For more information, see the system integration images contained in the chapter titled "System requirements", as well as the connection overview below.
1FW6 | 145 |
Configuration Manual, 05/2009, |