Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB10-8Fxx

-xxB10-2Pxx

1FW6190

 

 

 

 

Rotor moment of inertia

JL

10-2kgm2

67.8

67.8

Phase resistance of winding at 20 °C

RSTR, 20

Ω

0.235

0.093

Phase inductance of winding

LSTR

mH

2.3

0.9

Data for main motor cooler *)

 

 

 

 

Maximum dissipated thermal power

QH,MAX

kW

4.51

4.41

Recommended minimum volume flow

H,MIN

l/min

6.7

6.7

Temperature increase of the coolant

ΔTH

K

9.7

9.5

Pressure drop

ΔpH

bar

0.8

0.8

Data for precision motor cooler *)

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.486

0.476

Recommended minimum volume flow

P,MIN

l/min

2.3

2.3

Temperature increase of the coolant

ΔTP

K

3

2.9

Pressure drop

ΔpH

bar

0.8

0.8

*) Parallel connection of main and precision motor cooler

258

1FW6 Built-in torque motors

Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7

Page 258
Image 258
Siemens 611 configurationmanual Technical data Symbol Unit XxB10-8Fxx XxB10-2Pxx 1FW6190