![](/images/new-backgrounds/1218570/218570473x1.webp)
Technical data and characteristics 14.2 Data sheets and diagrams
Technical data | Symbol | Unit |
|
|
1FW6160 |
|
|
|
|
Rotor moment of inertia | JL | 36 | 36 | |
Phase resistance of winding at 20 °C | RSTR, 20 | Ω | 0.182 | 0.0906 |
Phase inductance of winding | LSTR | mH | 1.8 | 0.9 |
Data for main motor cooler *) |
|
|
|
|
Maximum dissipated thermal power | QH,MAX | kW | 3.68 | 3.59 |
Recommended minimum volume flow | H,MIN | l/min | 6.4 | 6.4 |
Temperature increase of the coolant | ΔTH | K | 8.3 | 8.1 |
Pressure drop | ΔpH | bar | 0.8 | 0.8 |
Data for precision motor cooler *) |
|
|
|
|
Maximum dissipated thermal power | QP,MAX | kW | 0.397 | 0.387 |
Recommended minimum volume flow | P,MIN | l/min | 2.5 | 2.5 |
Temperature increase of the coolant | ΔTP | K | 2.3 | 2.2 |
Pressure drop | ΔpH | bar | 0.8 | 0.8 |
*) Parallel connection of main and precision motor cooler
1FW6 | 237 |
Configuration Manual, 05/2009, |