Siemens 611 configurationmanual Technical data Symbol Unit, 1FW6160 Boundary conditions

Models: 611

1 324
Download 324 pages 4.89 Kb
Page 232
Image 232

Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB07-1Jxx

-xxB07-2Jxx

-xxB07-5Gxx

1FW6160

 

 

 

 

 

Data for precision motor cooler *)

 

 

 

 

 

 

 

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.291

0.292

0.294

Recommended minimum volume flow

P,MIN

l/min

1.8

1.8

1.8

Temperature increase of the coolant

ΔTP

K

2.3

2.3

2.3

Pressure drop

ΔpH

bar

0.4

0.4

0.4

*) Parallel connection of main and precision motor cooler

 

 

 

 

Table 14- 15 1FW6160-xxB07-8Fxx

 

 

 

 

 

 

 

 

 

 

 

Technical data

Symbol

Unit

-xxB07-8Fxx

 

 

1FW6160

 

 

 

 

 

Boundary conditions

 

 

 

 

 

DC link voltages

UZK

V

600

 

 

Water cooling inlet temperature

TVORL

°C

35

 

 

Rated temperature of winding

TN

°C

130

 

 

Rated data

 

 

 

 

 

Rated torque

MN

Nm

432

 

 

Rated current

IN

A

51

 

 

Maximum speed at rated torque

nMAX,MN

rpm

610

 

 

Rated power dissipation

PV,N

kW

3.73

 

 

Limit data

 

 

 

 

 

Maximum torque

MMAX

Nm

1000

 

 

Maximum current

IMAX

A

140

 

 

Electric power of motor at MMAX

PEL,MAX

kW

46.7

 

 

Maximum speed at maximum torque

nMAX,MMAX

rpm

330

 

 

No-load speed

nMAX,0

rpm

770

 

 

Torque at n = 1 [rpm]

M0

Nm

653

 

 

Current at M0 and n = 1 [rpm]

I0

A

80

 

 

Thermal static torque

M0*

Nm

462

 

 

Thermal stall current

I0*

A

55

 

 

Physical constants

 

 

 

 

 

Torque constant at 20 °C

kT,20

Nm/A

8.34

 

 

Voltage constant

kE

V/(1000/min)

504.3

 

 

Motor constant at 20 °C

kM,20

Nm/(W)0.5

11

 

 

Thermal time constant

tTH

s

180

 

 

No. of pole pairs

p

-

35

 

 

Cogging torque

MCOG

Nm

3.3

 

 

Stator mass

mS

kg

36.2

 

 

Rotor mass

mL

kg

12.1

 

 

232

 

 

 