Siemens 611 configurationmanual 294

Models: 611

1 324
Download 324 pages 4.89 Kb
Page 294
Image 294

Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB11-7Axx

-xxB11-0Lxx

-xxB11-2Pxx

1FW6290

 

 

 

 

 

Data for precision motor cooler *)

 

 

 

 

 

 

 

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.577

0.578

0.58

Recommended minimum volume flow

P,MIN

l/min

3.4

3.4

3.4

Temperature increase of the coolant

ΔTP

K

2.4

2.4

2.4

Pressure drop

ΔpH

bar

0.8

0.8

0.8

*) Parallel connection of main and precision motor cooler

294

1FW6 Built-in torque motors

Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7

Page 294
Image 294
Siemens 611 configurationmanual 294