Technical data and characteristics 14.2 Data sheets and diagrams

Technical data

Symbol

Unit

-xxB15-2Pxx

-xxB15-0Wxx

1FW6160

 

 

 

 

Rotor moment of inertia

JL

10-2kgm2

53.1

53.1

Phase resistance of winding at 20 °C

RSTR, 20

Ω

0.127

0.0636

Phase inductance of winding

LSTR

mH

1.4

0.7

Data for main motor cooler *)

 

 

 

 

Maximum dissipated thermal power

QH,MAX

kW

5.01

5.14

Recommended minimum volume flow

H,MIN

l/min

8.9

8.9

Temperature increase of the coolant

ΔTH

K

8.1

8.3

Pressure drop

ΔpH

bar

1.4

1.4

Data for precision motor cooler *)

 

 

 

 

Maximum dissipated thermal power

QP,MAX

kW

0.54

0.554

Recommended minimum volume flow

P,MIN

l/min

3.6

3.6

Temperature increase of the coolant

ΔTP

K

2.2

2.2

Pressure drop

ΔpH

bar

1.4

1.4

*) Parallel connection of main and precision motor cooler