the serial interface, the HTTP client will go from service state "Up" to service

 

 

state "Closing" (see parameters <srvState> and <srvState> for detail).

 

 

Finally, the URC "^SISW: x, 2" indicates that all data have been transferred and

 

 

the service can be closed with AT^SISC.

 

 

 

hcUsrAgent

The user agent string must be set by the application to identify the mobile. Usu-

 

 

ally operation system and software version info is set with this browser identi-

 

 

fier.

 

 

 

 

Length: 0 ... 63

 

 

 

hcMethod

HTTP method specification: 0=GET, 1=POST, 2=HEAD.

 

 

 

hcProp

Parameter for several HTTP settings.

 

 

 

 

Length: 0 ... 127

 

 

 

 

The general format is 'key': <space> 'value' "\0d\0a".

 

 

 

 

Multiple settings can be given separated by "\0d\0a" sequences within the

 

 

string.

 

 

 

 

Possible 'key' values are defined at HTTP/1.1 Standard RFC 2616.

 

 

 

hcRedir

This flag controls the redirection mechanism of the MC55 acting as HTTP client

 

 

(numeric).

 

 

 

 

If "hcRedir" = 0: No redirection.

 

 

 

 

If "hcRedir" = 1: The client automatically sends a new HTTP request if the

 

 

server answers with a redirect code (range 30x).

 

 

 

 

Default is 1.

 

 

 

hcAuth

If set ("hcAuth" = 1) this flag determines that the HTTP client will automatically

 

 

answer on authentication requests from the server with the current "passwd"

 

 

and "user" parameter settings. If these parameters are not specified the MC55

 

 

will terminate the HTTP connection and send an indication to the TA.

 

 

 

 

Default is 1.

 

 

 

smFrom

Email sender address, i.e. "MAIL FROM" address (string).

 

 

 

 

Length: 6 ... 256

 

 

 

 

A valid address parameter consists of local part and domain name delimited by

 

 

a '@' character, e.g. "john.smith@somedomain.de".

 

 

 

smRcpt

Recipient address of the email, i.e. "RCPT TO" address (string).

 

 

 

 

Length: 6 ... 256

 

 

 

 

If multiple recipient addresses are to be supplied the comma character is used

 

 

as delimiter to separate individual address values, e.g. "john.smith@somedo-

 

 

main.de,tom.meier@somedomain.de".

 

 

 

smCC

CC recipient address of the email (string).

 

 

 

 

Length: 6 ... 256

 

 

 

 

If multiple CC recipient addresses are to be supplied the comma character is

 

 

used as delimiter to separate individual address values, e.g.

 

 

"john.smith@somedomain.de,tom.meier@somedomain.de".

 

 

 

smSubj

Subject content of the email (string).

 

 

 

 

Length: 0 ... 256

 

 

 

 

If no subject is supplied the email will be sent with an empty subject.

 

 

 

smHdr

This parameter, if set, will be appended at the end of the email header section

 

 

(string).

 

 

 

 

Length: 0... 256

 

 

 

 

Hence, it serves as a generic header field parameter which allows the user to

 

 

provide any email header field. It is the user's responsibility to provide correct

 

 

header fields!

 

 

 

 

String of max. 256 characters.

 

 

 

 

Example for multipart MIME messages:

 

 

 

 

"Content-Type: multipart/mixed".

 

 

 

smAuth

SMTP authentication control flag (numeric).

 

 

 

 

If disabled (<srvParmValue> "0" by default), MC55 performs action without

 

 

SMTP authentication.

 

 

 

 

If enabled (<srvParmValue> "1") authentication procedure with the SMTP

 

 

server will be performed by means of supported authentication methods, using

 

 

 

 

 

MC55_ATC_V04.00

Page 233 of 475

3/17/06

 

Confidential / Released

 

 

 

Page 233
Image 233
Siemens MC55 AT manual Content-Type multipart/mixed