18.5AT^SCTM Set critical operating temperature presentation mode or query temperature

Use this command to monitor the temperature range of the module and the battery. The write command enables or disables the presentation of URCs to report critical temperature limits.

CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report mode: URCs can be always displayed regardless of the selected mode <n>.

Syntax

Test Command

AT^SCTM=?

Response(s)

^SCTM:(list of supported <n>s)

OK

Read Command

AT^SCTM?

Response(s)

^SCTM: <n>, <m>

OK ERROR +CME ERROR

Write Command

AT^SCTM=<n>

Response(s)

OK ERROR +CME ERROR

Reference(s)

SIEMENS

PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge  Last

! % % % % % % % !

Unsolicited Result Codes

URC 1

URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level, or when it is back to normal.

^SCTM_A: <m>

for battery temperature

URC 2

^SCTM_B: <m>

for module (board) temperature

MC55_ATC_V04.00

Page 434 of 475

3/17/06

Confidential / Released

 

 

Page 434