Siemens MC55 AT manual Summary of Fax Class 2 URCs defined by EIA PN-2388, +Fcon

Models: MC55 AT

1 475
Download 475 pages 54.64 Kb
Page 303
Image 303

<wd>(num)

Page Width

 

[0]

1728 pixels in 215mm

1

2048 pixels in 255 mm

2

2432 pixels in 303 mm

3

1216 pixels in 151 mm

4

864 pixels in 107 mm

Note

The host application is not required to support all values of the parameters listed above. Depending on the application design it may be sufficient to implement only the default values. See T.31, T.32 and EIA PN-2388 specifications for further advice.

12.1.1Summary of Fax Class 2 URCs defined by EIA PN-2388

The following URCs are messages indicated in communication only. The URCs are not user definable.

Table 12.1: Summary of Fax Class 2 URCs defined by EIA PN-2388

URC

Meaning

+FCON

Indicates connection with a fax machine.

+FCSI: <id>

Reports the remote ID, called station ID.

+FDCS: <vr>, <br>, <wd>, <ln>, <df>,

Reports current session parameters (refer to EIA PN-2388, Table

<ec>, <bf>, <st>

3.10).

+FDIS: <vr>, <br>, <wd>, <ln>, <df>, <ec>,

Reports the remote station capabilities (refer to EIA PN-2388,

<bf>, <st>

Table 3.10).

+FET: <stat>

Post page message. Indicates whether or not further pages or

 

documents are pending.

+FHNG: <stat>

Reports that call has been terminated and indicates status.

+FNSF: "<param>"

Reports non-standard setup frame.

+FPTS: "<stat>"

Reports the status of received pages.

+FTSI: "<id>"

Reports the remote ID, transmit station ID.

 

 