Siemens MC55 AT manual Also refer to .1, Call Status Information

Models: MC55 AT

1 475
Download 475 pages 54.64 Kb
Page 63
Image 63

<indDescr>(str)

String values and their <indValue> ranges.

More indications are available via AT^SIND. Therefore use of AT^SIND for control of all indications is recom- mended.

The following indications are accessible via AT+CIND:

"battchg"

Battery charge level 0..4 or 5 if no measuring is performed, e.g because no bat-

 

tery is connected. Also refer to AT^SBC.

"signal"

Signal quality (0..7) or (99) if not measurable

 

The indicated value is the bit error rate of the signal received. Bit errors are esti-

 

mated values. See also AT+CSQ.

"service"

Service availability (0-1)

 

0: Not registered to any network

 

1: Registered to home network or, if "roam"=1 then registered to another net-

 

work

"sounder"

Sounder activity (0-1)

 

Reports every event that causes the ME to generate a tone.

 

Value 1 means for example:

 

Incoming call - ME is ringing. Note that the URC "+CIEV: sounder" will be out-

 

put only if ringing tones are activated with AT^SRTC.

 

Waiting call - ME generates waiting call tone (if call waiting is enabled).

 

Outgoing call - ME generates Call Progress tone.

 

Outgoing call - ME generates BUSY tone.

 

The value changes to 0 when the tone stops.

"message"

Unread short message at memory location <mem1> (0-1); refer to AT+CPMS

"call"

Call in progress (0-1). Indicator value is "1" if at least one call is in state "active"

 

or "held".

 

Depending on the parameter <succ> selected with AT^SCFG the indicator

 

"call" will be issued

 

• when a state transition ends in state "active" or state "unknown", if

 

<succ>="restricted",

 

• when any state transition (including transitions beginning or ending in state

 

"unknown") occurs in the list of active calls or when a traffic channel is

 

established, if <succ>="verbose".

 

Also refer to Section 7.1, Call Status Information.

"roam"

Roaming indicator (0-1)

 

0: Registered to home network or not registered

 

1: Registered to other network

"smsfull"

A short message memory storage in the MT has become full (1) or memory

 

locations are available (0), i.e. range is (0-1)

"rssi"

Received signal (field) strength (0..5) or (99) if not measurable

 

0: signal strength <= -112 dbm

 

1-4: signal strength in 15 dbm steps

 

5: signal strength >= -51 dbm

 

Received signal (field) strength can also be obtained with AT+CSQ. However,

 

the signal strength is scaled to value range 0..31 by this command.

 

 

<mode>(num)

 

0

Indicator is deregistered. The indicator will not be presented as "+CIEV" URC,

 

but can be queried with AT+CIND?.