<MicVccState>(num)

Microphone supply voltage control status.

0

Supply voltage was set to a constant value.

2

Supply voltage state is controlled by the ME and depends on parameter data

 

set of the selected audio mode.

Notes

The programmable power supply of the MICP2 line gives you greater flexibility in connecting audio accesso- ries or using MICP2 for a variety of functions other than audio. A detailed description of the extended usage of MICP2 can be found in [8].

During an active call, users should be aware that when they switch back and forth between different audio modes (for example handsfree on/off) the value of <MicSwitch> does not change, i.e. the microphone mode is retained until explicitly changed.