12.20AT+FPHCTO DTE Phase C Response Timeout

The timeout value <tout> determines how long the DCE will wait for a command after reaching the end of data when transmitting in Phase C. When timeout is reached, the DCE assumes that there are no more pages or doc- uments to send.

Syntax

Read Command

AT+FPHCTO?

Response(s)

<tout>

OK

Write Command

AT+FPHCTO=<tout>

Response(s)

OK

If error is related to ME functionality

ERROR

Reference(s)

EIA PN-2388

 

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

Charge

 Last

 

 

 

 

 

 

 

 

 

 

 

 

!

%

!

%

!

!

!

! !

 

 

 

 

 

 

 

 

 

 

 

Parameter Description

<tout>(num)

Timeout

Value in 100ms units 0...30(P)...255

Note

Used for Fax Class 2 only.