2.14AT^SM20 Set M20 compatibility mode

M20 is an earlier, widely used SIEMENS GSM engine. The AT^SM20 command selects different modes of responses returned upon execution of the commands ATD and sms commands like e.g. AT+CMGW. Please note that the AT^SM20 command has no effect on any other features and is not intended to adjust other differences between M20 and MC55.

Syntax

Test Command

AT^SM20=?

Response(s)

OK

Read Command

AT^SM20?

Response(s)

^SM20:<CallMode>, <CmgwMode>

OK

Write Command

AT^SM20=<CallMode>[, <CmgwMode>]

Response(s)

OK

Reference(s)

SIEMENS

PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge  Last

! % % % % % ! ! !

Parameter Description

<CallMode>(num)

Call setup response mode

 

Applies only to voice calls.

 

0

Set compatibility to Siemens mobile phones.

 

ME will return "OK" immediately after attempting a call with the ATD command.

 

In case of failure, additional call release indications, such as "NO DIAL TONE,

 

"NO CARRIER", "BUSY" will follow.

1(&F)

Default call setup mode, compatible to M20.

 

ME will return "OK" in case of a successful connection, otherwise one of the

 

call release indications "NO DIAL TONE, "NO CARRIER", "BUSY" are indi-

 

cated.

<CmgwMode>(num)

Response mode for sending and writing short messages

Applies to the sms commands like e.g. AT+CMGS and AT+CMGW command.

0

Set compatibility to Siemens mobile phones.

 

ME will return +CMS ERROR: <err> when writing or sending of short mes-

 

sages fails.

1(&F)

Default mode for sending and writing short messages, compatible to M20.

 

ME will return "OK", no matter whether or not sms command was successfully

 

executed.

MC55_ATC_V04.00