Siemens MC55 AT manual Delaynum, Reliabilitynum

Models: MC55 AT

1 475
Download 475 pages 54.64 Kb
Page 285
Image 285

2

Normal priority

 

Service commitments shall be maintained ahead of precedence class 3

3

Low priority

 

Service commitments shall be maintained

 

 

<delay>(num)

 

Delay class

 

This parameter defines the end-to-end transfer delay incurred in the transmission of SDUs through the GPRS network(s).

[0]

network subscribed value

 

 

 

1..4

with SDU size = 128 octets:

 

 

 

 

 

 

 

 

 

Delay Class

Mean Transfer Delay

95 percentile

 

 

1

(Predictive)

<0.5

<1.5

 

 

 

2

(Predictive)

<5

<25

 

 

 

3

(Predictive)

<50

<250

 

 

 

4

(Best Effort)

Unspecified

-

 

 

 

with SDU size = 1024 octets:

 

 

 

 

 

 

 

 

 

Delay Class

Mean Transfer Delay

95 percentile

 

 

1

(Predictive)

<0.5

<1.5

 

 

 

2

(Predictive)

<5

<25

 

 

 

3

(Predictive)

<50

<250

 

 

 

4

(Best Effort)

Unspecified

-

 

 

 

 

 

 

 

 

 

<reliability>(num)

 

 

 

 

 

 

Reliability class

 

 

 

 

 

[0]

network subscribed value

 

 

 

1

Non real-time traffic, error-sensitive application that cannot cope with data loss

2

Non real-time traffic, error-sensitive application that can cope with infrequent

 

 

data loss

 

 

 

3

Non real-time traffic, error-sensitive application that can cope with data loss,

 

 

GMM/SM, and SMS

 

 

 

4

Real-time traffic, error-sensitive application that can cope with data loss

5

Real-time traffic, error non-sensitive application that can cope with data loss

 

 

 

 

 

 

 

 

<peak>(num)

 

 

 

 

 

 

Peak throughput class

 

 

 

 

 

 

in octets per second

 

 

 

 

 

[0]

network subscribed value

 

 

 

1

Up to 1 000 (8 kbit/s)

 

 

 

2

Up to 2 000 (16 kbit/s)

 

 

 

3

Up to 4 000 (32 kbit/s)

 

 

 

4

Up to 8 000 (64 kbit/s)

 

 

 

5

Up to 16 000 (128 kbit/s)

 

 

 

 

 

 

 

 

 

MC55_ATC_V04.00

 