Siemens MC55 AT manual HandOverStatusstr+CSCS

Models: MC55 AT

1 475
Download 475 pages 54.64 Kb
Page 55
Image 55

<psm9to>(str)(+CSCS)

Power saving mode 9 timeout

This parameter can be used to query or configure the wake up time for power saving mode 9 (see AT+CFUN with parameter <fun>=9).

Parameter is global for the ME, volatile and will not be reset by AT&F.

5...20(P)...36000

The granularity of the timeout value is 100ms (i.e. a value of 10 equal 1 sec-

 

ond). The minimum timeout value that can be applied is 5, but accuracy is only

 

guaranteed for timeout values greater than 20.

<HandOverStatus>(str)(+CSCS)

Call Handover Status

This parameter offers a workaround to prevent problems during call handover into the 1900 MHz (or 1800 MHz) band, caused by non-conforming configurations of the 1900 MHz (or 1800 MHz) GSM network.

"0"(P)

Disable workaround.

"1"

Enable workaround. This value should be selected when handover into a 1900

 

MHz (or 1800 MHz) GSM network fails. If required for permanent use the value

 

needs to be set each time the ME is restarted.

<tcpIrt>(str)(+CSCS)

Initial Retransmission Timeout (IRT)

1...3(&F)(D)...60

This parameter determines the time (in seconds) the TCP/IP stack will wait

 

before starting the first retransmission of packets during the initial connection

establishment phase.

The TCP protocol ensures the retransmission of packets several times at increasing intervals until some upper limit is reached.

This mechanism prevents packet loss and serious congestion problems. In addition, the parameters <tcpMr> and <tcpOt> can be set to further optimize this mechanism for special conditions depending on the mobile network.

Parameter is global for the ME and non-volatile. Use of default value is recom- mended. If changed the new value takes effect the next time you start an Inter- net service with AT^SISO.

<tcpMr>(str)(+CSCS)

Maximum Number of Retransmissions (MR)

1...10(&F)(D)...30

This parameter determines the maximum number of times to retransmit TCP

 

packets.

The value set with <tcpMr> will be assumed as default for the <srv- ParmTag> "tcpMR" when a new service profile is created with AT^SISS. In each service profile, you can set another "tcpMR" value which has precedence over the global value set with AT^SCFG. Existing service profiles are not affected when you change the global value via AT^SCFG.

Parameter is global for the ME and non-volatile. Use of default value is recom- mended.

<tcpOt>(str)(+CSCS)

Overall TCP Timer for outstanding connections (tcpOT)

 

1...6000(&F)(D)

This parameter specifies the number of seconds to wait before closing a con-

 

 

nection if TCP/IP packets are not acknowledged.

 

 

 

 

Setting the maximum value is practically equivalent to deactivating the tcpOT

 

 

mechanism because the maximum time would never be reached by the TCP/

 

 

IP stack.

 

 

 

 

The value set with <tcpOt> will be assumed as default for the <srv-

 

 

ParmTag> "tcpOT" when a new service profile is created with AT^SISS. How-

 

 

 

 

 

MC55_ATC_V04.00

Page 55 of 475

3/17/06

 

Confidential / Released

 

 

 

Page 55
Image 55
Siemens MC55 AT manual HandOverStatusstr+CSCS