Siemens MC55 AT Wake up the ME from Sleep mode, +CMTI SM,5, AT+CFUN? +CFUN OK AT+CFUN=1, Fun=0

Models: MC55 AT

1 475
Download 475 pages 54.64 Kb
Page 40
Image 40

When, for example, an SMS is being received and indicated by an unsolicited result code (URC), the ME wakes up to full operation.

+CMTI: "SM",5

Note that the URC used in this example will appear only, if

 

AT+CNMI=1,1 was configured before.

After this, you may want to verify the operating status:

 

 

AT+CFUN?

 

+CFUN: 1

Indicates that ME has entered full functionality mode.

EXAMPLE 3

To stop CYCLIC SLEEP mode and return to full functionality:

AT+CFUN? +CFUN: 5

OK AT+CFUN=1

OK

Remember that this approach is not applicable to the NON-CYCLIC SLEEP mode (since the serial interface is disabled). The NON-CYCLIC SLEEP mode ends with the first wake-up event.

EXAMPLE 4

 

 

To reset and restart the ME:

 

 

 

 

 

AT+CFUN=1,1

or alternatively, AT+CFUN=0,1 or 5,1 or 6,1 or 7,1 or 8,1 or 9,1

 

OK

 

 

^SYSSTART

The ^SYSSTART URC confirms that the ME has been rebooted. Note

 

 

that ^SYSSTART appears only if AT+IPR 0. If the ME is in autobaud

 

 

mode, it is recommended to wait 3 to 5 seconds before entering the first

 

 

AT command. Remember to enter the SIM PIN after restart.

2.8.1Wake up the ME from SLEEP mode

A wake-up event is any event that causes the ME to draw more current. Depending on the selected mode, the wake-up event either switches the SLEEP mode off and takes the ME back to full functionality AT+CFUN=1, or activates the ME temporarily without terminating the selected SLEEP mode.

Definitions of the state transitions described in Table 2.3:

Quit: ME exits SLEEP mode.

Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time after the last character was sent or received on the serial interface.

No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.

Table 2.3: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes

Event

Selected mode:

Selected mode:

Selected mode:

 

<fun>=0

<fun>=5 or 6

<fun>=7 or 8 or 9

Ignition line

No effect

No effect

No effect

/RTS0 or /RTS1 activation

Quit

No effect (RTS is only

Mode 7 and 8: No effect

 

 

used for flow control)

(RTS is only used for flow

 

 

 

control)

 

 

 

Mode 9: Temporary

Unsolicited Result Code

Quit

Quit

Temporary

(URC)

 

 

 

Incoming voice or data

Quit

Quit

Temporary

call

 

 

 

 

 

 

 

MC55_ATC_V04.00

Page 40 of 475

3/17/06

Confidential / Released

 

 

Page 40
Image 40
Siemens MC55 AT manual Wake up the ME from Sleep mode, +CMTI SM,5, AT+CFUN? +CFUN OK AT+CFUN=1, AT+CFUN=1,1, Fun=0