When, for example, an SMS is being received and indicated by an unsolicited result code (URC), the ME wakes up to full operation.

+CMTI: "SM",5

Note that the URC used in this example will appear only, if

 

AT+CNMI=1,1 was configured before.

After this, you may want to verify the operating status:

 

 

AT+CFUN?

 

+CFUN: 1

Indicates that ME has entered full functionality mode.

EXAMPLE 3

To stop CYCLIC SLEEP mode and return to full functionality:

AT+CFUN? +CFUN: 5

OK AT+CFUN=1

OK

Remember that this approach is not applicable to the NON-CYCLIC SLEEP mode (since the serial interface is disabled). The NON-CYCLIC SLEEP mode ends with the first wake-up event.

EXAMPLE 4

 

 

To reset and restart the ME:

 

 

 

 

 

AT+CFUN=1,1

or alternatively, AT+CFUN=0,1 or 5,1 or 6,1 or 7,1 or 8,1 or 9,1

 

OK

 

 

^SYSSTART

The ^SYSSTART URC confirms that the ME has been rebooted. Note

 

 

that ^SYSSTART appears only if AT+IPR 0. If the ME is in autobaud

 

 

mode, it is recommended to wait 3 to 5 seconds before entering the first

 

 

AT command. Remember to enter the SIM PIN after restart.

2.8.1Wake up the ME from SLEEP mode

A wake-up event is any event that causes the ME to draw more current. Depending on the selected mode, the wake-up event either switches the SLEEP mode off and takes the ME back to full functionality AT+CFUN=1, or activates the ME temporarily without terminating the selected SLEEP mode.

Definitions of the state transitions described in Table 2.3:

Quit: ME exits SLEEP mode.

Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time after the last character was sent or received on the serial interface.

No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.

Table 2.3: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes

Event

Selected mode:

Selected mode:

Selected mode:

 

<fun>=0

<fun>=5 or 6

<fun>=7 or 8 or 9

Ignition line

No effect

No effect

No effect

/RTS0 or /RTS1 activation

Quit

No effect (RTS is only

Mode 7 and 8: No effect

 

 

used for flow control)

(RTS is only used for flow

 

 

 

control)

 

 

 

Mode 9: Temporary

Unsolicited Result Code

Quit

Quit

Temporary

(URC)

 

 

 

Incoming voice or data

Quit

Quit

Temporary

call

 

 

 

 

 

 

 

MC55_ATC_V04.00