Siemens SIMATIC NET PROFIBUS manual PG socket

Models: SIMATIC NET PROFIBUS

1 490
Download 490 pages 10.94 Kb
Page 133
Image 133

Passive Components for RS-485 Networks

Technical Specifications

The following table shows the technical data of the various bus connectors:

Table 4-7 Technical Specifications of the IP 20-compliant Bus Connectors

 

Order numbers:

6ES7 972-

6ES7 972-

6ES7 972-

6GK1 500-

 

 

... 0BA11-0XA0

... 0BA40-0XA0

0BA30-0XA0

0EA02

 

 

... 0BB11-0XA0

... 0BB40-0XA0

 

 

 

 

 

 

 

PG socket

0BA11: no

0BA40: no

no

no

 

 

0BB11: yes

0BB40: yes

 

 

 

 

 

 

 

Max. transmission

12 Mbps

12 Mbps

1.5 Mbps

12 Mbps

rate

 

 

 

 

 

 

 

 

 

Terminating resistor

integrated

integrated

no

integrated

and disconnect

 

 

 

 

function

 

 

 

 

 

 

 

 

 

Cable outlet

vertical

oblique 35_

oblique 30_

axial

 

 

 

 

 

Interfaces

 

 

 

 

S

to PROFIBUS

9-pin sub-D male

9-pin sub-D male

9-pin sub-D male

9-pin sub-D male

 

node

connector

connector

connector

connector

S

to PROFIBUS

4 modular

4 modular

4 insulation

4 modular

 

LAN cable

terminals for wires

terminals for wires

displacement

terminals for wires

 

 

up to 1.5 mm2

up to 1.5 mm2

terminals for wires

up to 1.5 mm2

 

 

 

 

0.644 " 0.04 mm

 

 

 

 

 

 

Connectable

8 " 0.5 mm

8 " 0.5 mm

8 " 0.5 mm

8 " 0.5 mm

PROFIBUS cable

 

 

 

 

diameter

 

 

 

 

 

 

 

 

 

Power supply (must

4.75 to 5.25 V DC

4.75 to 5.25 V DC

---

4.75 to 5.25 V DC

be supplied by DTE)

 

 

 

 

 

 

 

 

 

Current consumption

max. 5 mA

max. 5 mA

---

max. 5 mA

 

 

 

 

 

Permitted ambient

 

 

 

 

conditions

 

 

 

 

S

Operating

0 _C to +60 _C

0 _C to +60 _C

0 _C to +60 _C

0 _C to +55 _C

 

temperature

-25 _C to +80 _C

-25 _C to +80 _C

-25 _C to +80 _C

-25 _C to +70 _C

S

Transport/storage

 

 

 

 

 

temperature

max. 75 % at

max. 75 % at

max. 75 % at

max. 95 % at

S

Relative humidity

+25 _C

+25 _C

+25 _C

+25 _C

 

 

 

 

 

Dimensions (in mm)

15.8 54 34

16 54 38

15 58 34

15 39 57

 

 

 

 

 

Weight

approx. 40 g

approx. 40 g

approx. 30 g

approx. 100 g

 

 

 

 

 

 

Disconnect Function

The disconnect function means that the remaining LAN cable is disconnected from the bus when the terminating resistor is activated. If the terminating resistor is accidentally activated in the middle of the LAN cable, the error can be recognized and localized immediately due to the nodes that are no longer accessible.

PROFIBUS Networks SIMATIC NET

4-35

6GK1970-5CA20-0AA1 Release 2 05/2000

Page 133
Image 133
Siemens SIMATIC NET PROFIBUS manual PG socket