Passive Components for Electrical Networks

Table 7-5 Technical Specifications of the Flexible Fiber-Optic Trailing Cable and the SIENOPYR Duplex Fiber-Optic Marine Cable

Cable Type

Flexible Fiber-Optic

 

SIENOPYR

 

Trailing Cable

 

Duplex Fiber-Optic

 

 

 

Marine Cable

 

 

 

Strain relief

GFK central element, Aramid

Aramid yarn

 

yarn

 

 

 

 

 

Outer jacket/color of cable

PUR, black

SHF1 mixture/black

 

 

 

 

Dimensions Basic element

(3.5 ± 0.2) mm

(2.9 ±

0.2) mm

 

 

 

 

Outer dimensions

approx. 12.9 mm

(13.3 ±

0.5) mm

 

 

 

Cable weight

approx. 136 kg/km

approx. 220 kg/km

 

 

 

Permitted tensile load

<= 2000 N (brief)

<= 500 N (brief)

 

<=1000 N (permanent)

<= 250 N (permanent)

 

 

 

Bending radii

150 mm

133 mm (single)

 

Max. 100,000 bending cycles

266 mm (multiple)

 

 

 

Installation temperature

-5°C to +50° C

-10°C to +50° C

 

 

 

Operating temperature

-25°C to +60° C

-40°C to +80° C 1)

 

 

-40°C to +70° C 2)

 

 

 

Storage temperature

-25°C to +70° C

-40°C to +80° C

 

 

 

Resistance to fire

Complying with IEC 60332-1

Complying with IEC 60332-3 cat.

 

 

A

 

 

 

 

 

Free of halogens

no

yes

 

 

 

 

 

UL approval

no

no

 

 

 

 

 

Ship building approval

no

yes

 

 

 

 

 

1)With no load on copper cores

2)With maximum load on copper cores (6 A)

7-16

PROFIBUS Networks SIMATIC NET

6GK1970-5CA20-0AA1 Release 2 05/2000