Passive Components for Electrical Networks

Technical Specifications

Tables 7-4 and 7-5 provide an overview of the technical specifications of all SIMATIC NET glass fiber-optic cables.

Table 7-4 Technical Specifications of the INDOOR Fiber-Optic Cable and Fiber-Optic Standard Cable

Cable Type

Fiber-Optic

Standard Cable

INDOOR Fiber-Optic

Cable

Areas of application

Universal cable for use indoors

Halogen-free and extremely

 

and outdoors

flame-retardant cable for indoor

 

 

use that can be walked on

 

 

 

Available as

Preassembled cable with 4

Preassembled cable with 4

 

BFOC connectors in fixed

BFOC connectors in fixed

 

lengths, also available in meters

lengths

 

 

 

Cable type

AT-VYY 2G62.5/125

I-VHH 2G62.5/125

(standard designation)

3.1B200+0.8F600 F

3.2B200+0.9F600 F

 

 

TB3 FRNC OR

 

 

 

Fiber type

Multimode graded fiber 62.5/125

Multimode graded fiber 62.5/125

 

m

m

 

 

 

Power loss at 850 nm

<= 3.1 dB/km

<= 3.2 dB/km

Power loss at 1300 nm

<= 0.8 dB/km

<= 0.9 dB/km

 

 

 

Modal bandwidth

 

 

at 850 nm

200 MHz *km

200 MHz *km

at 1300 nm

600 MHz *km

600 MHz *km

 

 

 

Number of fibers

2

2

 

 

 

Cable design

Splittable

Splittable

 

outdoor cable

indoor cable

 

 

 

Core type

Compact core

Fixed core

 

 

 

Basic element materials

PVC, gray

Copolymer, orange

 

 

(FRNC)

 

 

 

Strain relief

Aramid yarn and

Aramid yarn

 

impregnated glass fiber yarn

 

 

 

 

Outer jacket/

PVC/black

Copolymer/

color of cable

 

bright orange (FRNC)

 

 

 

Dimensions of

(3.5 ± 0.2) mm

2.9 mm

basic element

 

 

 

 

 

Outer dimensions

(6.3 x 9.8) ± 0.4 mm

approx. 3.9 x 6.8 mm

 

 

 

Cable weight

approx. 74 kg/km

approx. 30 kg/km

 

 

 

Permitted tensile load

<= 370 N (in operation)

<=200 N (in operation)

 

<= 500 N (brief)

<= 800 N (brief)

 

 

 

Bending radii

100 mm

100 mm (during installation)

 

Only the flat surface

60 mm (in operation)

 

 

Only the flat surface

 

 

 

Transverse compressive strength

5,000 N/10 cm

3,000 N/10 cm (brief)

 

 

1,000 N/10 cm (permanent)

 

 

 

7-14

PROFIBUS Networks SIMATIC NET

6GK1970-5CA20-0AA1 Release 2 05/2000