Siemens SIMATIC NET PROFIBUS manual LAN Cables for Profibus

Models: SIMATIC NET PROFIBUS

1 490
Download 490 pages 10.94 Kb
Page 101
Image 101

Passive Components for RS-485 Networks

Table 4-1 LAN Cables for PROFIBUS (1)

Technical Specifications 1)

FC Standard

FC FRNC

 

FC Food

 

FC Robust

FC Under-

 

Cable Type

 

Cable

 

Cable

 

Cable

 

Cable

 

ground Cable

 

 

 

 

 

 

 

 

 

 

 

 

Order Number

 

6XV1 830

 

6XV1 830

 

6XV1 830

 

6XV1 830

 

6XV1 830

 

 

 

 

-0EH10

 

-0LH10

 

-0GH10

 

-0JH10

 

-3FH10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attenuation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at

16

MHz

< 42

dB/km

< 42

dB/km

< 42

dB/km

< 42

dB/km

< 42

dB/km

at

4

MHz

< 22

dB/km

< 22

dB/km

< 22

dB/km

< 22

dB/km

< 22

dB/km

at

38.4

kHz

<

4

dB/km

<

4

dB/km

<

4

dB/km

<

4

dB/km

<

4

dB/km

at

9.6

kHz

<2.5

dB/km

<2.5

dB/km

<2.5

dB/km

<2.5

dB/km

<2.5

dB/km

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Characteristic impedance

270 ±

 

270 ±

 

270 ±

 

270 ±

 

270 ±

 

at 9.6 kHz

 

27

27

27

27

27

at 31.25 kHz

 

-

 

 

 

-

 

 

 

-

 

 

 

-

 

 

 

-

 

 

 

at 38.4 kHz

 

185 ±

18.5

185 ±

18.5

185 ±

18.5

185 ±

18.5

185 ±

18.5

at 3 to 20 MHz

 

150 ±

15

150 ±

15

150 ±

15

150 ±

15

150 ±

15

Rated value

 

 

150

 

 

150

 

 

150

 

 

150

 

 

150

 

 

 

 

 

 

 

 

 

 

 

 

d.c. loop resistance

110 /km

110 /km

110 /km

110 /km

110 /km

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shield resistance

9.5

/km

9.5

/km

9.5

/km

9.5

/km

9.5

/km

 

 

 

 

 

 

Effective capacitance at

approx. 28.5

approx. 28.5

approx. 28.5

approx. 28.5

approx. 28.5

1 kHz

 

 

nF/km

 

nF/km

 

nF/km

 

nF/km

 

nF/km

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating voltage

100 V

 

100 V

 

100 V

 

100 V

 

100 V

 

(effective)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable type

 

02YY(ST)CY

02YSH(ST)CH

02YSY(ST)C2

02YSY(ST)C11

02YSY(ST)

standard code

 

1x2x0.64/2.55-

1x2x0.64/2.55-

Y

 

 

 

Y

 

 

 

CY2Y

 

 

 

 

 

150 KF 40

 

150 VI KF25

1x2x0.64/2.55-

1x2x0.64/2.5-

1x2x0.64/2.5-

 

 

 

FRNC VI

 

FRNC

 

150 KF40

 

150 KF40

 

150 KF 40 SW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRNC VI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sheath

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Material

 

PVC

 

 

FRNC

 

PE

 

 

PUR

 

 

PE/PVC

 

Color

 

 

violet

 

 

light violet

 

black

 

 

violet

 

 

black

 

 

Diameter

 

8.0 ± 0.4 mm

8.0 ± 0.4 mm

8.0 ± 0.4 mm

8.0 ± 0.4 mm

10.8 ±

0.5 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Permitted ambient conditions

-40°C + 60° C

-25°C + 60° C

-40°C + 60° C

-40°C + 60° C

-40°C + 60° C

– Operating temperature

– Transport/storage

-40°C + 60° C

-25°C + 60° C

-40°C + 60° C

-40°C + 60° C

-40°C + 60° C

temperature

 

-40°C + 60° C

-25°C + 60° C

-40°C + 60° C

-40°C + 60° C

-40°C + 60° C

– Installation temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bending radii

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One-time bending

75 mm

 

75 mm

 

75 mm

 

75 mm

 

80 mm

 

Repeated bending

150 mm

 

150 mm

 

150 mm

 

150 mm

 

150 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. tensile load

100 N

 

 

100 N

 

 

100 N

 

 

100 N

 

 

100 N

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight approx.

76 kg/km

 

67 kg/km

 

67 kg/km

 

73 kg/km

 

117 kg/km

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Halogen free

 

no

 

 

yes

 

 

no

 

 

no

 

 

no

 

 

 

 

 

 

 

 

 

 

Behavior in fire

flame-retardant

flame-retardant

flammable

 

flame-retardant

flammable

 

 

 

 

according to

according to

 

 

 

 

according to

 

 

 

 

 

 

 

VDE 0472

 

VDE 0472

 

 

 

 

 

VDE 0472

 

 

 

 

 

 

 

 

T804

 

 

T804

 

 

 

 

 

 

T804

 

 

 

 

 

 

 

 

 

test type C

 

test type C

 

 

 

 

 

test type B

 

 

 

 

 

 

 

 

 

 

 

 

 

Oil resistance

 

Conditionally

Conditionally

Conditionally

good resi-

 

Conditionally

 

 

 

resistant to mi-

resistant to mi-

resistant to mi-

stance to mine-

resistant to mi-

 

 

 

neral oil and

neral oil and

neral oil and

ral oil and

 

neral oil and

 

 

 

greases

 

greases

 

greases

 

greases

 

greases

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROFIBUS Networks SIMATIC NET

4-3

6GK1970-5CA20-0AA1 Release 2 05/2000

Page 101
Image 101