Infrared Link Modul (ILM)

6ZB530–3AC30–0BA1

 

 

9

Displays

 

 

 

 

 

POWER

 

 

 

 

 

 

green LED

not lit

No power supply or internal power supply defective or ribbon ca-

 

 

 

ble not plugged in.

 

 

 

 

 

 

lit green

Power supply OK

 

 

 

 

TX

 

 

 

 

 

 

yellow/orange LED

not lit

Data not sent optically

 

 

 

 

 

 

lit yellow

Data are sent, acknowledgment bit correctly received or acknow-

 

 

 

ledgment bit mechanism not activated.

 

 

 

 

 

 

lit orange

Data being sent, acknowledgment bit activated but not correctly

 

 

 

received.

 

 

 

 

RX

 

 

 

 

 

 

yellow LED

not lit

Data not optically received

 

 

 

 

 

 

lit yellow

Data optically received

 

 

 

 

LOW

 

 

 

 

 

 

 

red LED

 

not lit

Receive level OK (RX LED lit)

 

 

 

no receive level (RX LED also not lit)

 

 

 

 

 

 

lit red

Data optically received, the level is however low (RX LED also lit)

 

 

 

risk of data errors

 

 

 

 

ERROR

 

 

 

 

 

 

 

red LED

 

not lit

Infrared level at receiver is not critical

 

 

 

 

 

 

lit red

Infrared level at receiver is critical, risk of data errors

 

 

 

 