Infrared Link Modul (ILM)

6ZB530–3AC30–0BA1

 

 

11

Technical Specifications

 

 

 

 

 

Operating voltage

24 V DC (20 V to 30 V)

 

Safety extra-low voltage (SELV)

 

 

 

 

 

Current consumption

ma. 300 mA

 

 

 

Transmission rate

9.600 Kbps; 19.200 Kbps; 45.45 Kbps, 93.75 Kbps;

 

 

 

187.5 Kbps; 500 Kbps; 1.5 Mbps;

 

 

 

 

Setting the transmission rate

Using 3 DIP switches

 

 

 

 

Setting the mode

Using 5 DIP switches

 

 

 

 

 

Bit error rate

 

<10–6

 

Signal delay time

<= 6 bit times

 

RS 485 input

infrared output

 

 

 

 

 

Signal delay time

<= 3 bit times

 

infrared input

RS 485 output

 

 

 

 

 

Electrical channel

 

 

 

 

 

Input/output signal

RS 485 level

 

 

 

 

Input voltage dielectric strength

–10 V to )15 V

 

 

 

 

 

Interface signals

 

Ungrounded within the SELV limits

 

 

 

 

Terminating resistors

Activated with DIP switch

 

 

 

 

 

Optical channel

 

 

 

 

 

 

 

Optical source

 

21 LEDs

 

 

 

 

Optical power

 

280 mW effective with alternating 0–1 sequence

 

 

 

Receiver sensitivity

0.5 A/W

 

 

 

 

– 28 dBmW

 

 

 

 

 

Wavelength

 

860 nm to 880 nm

 

 

 

 

Distance between two ILMs

maximum 15 m in the optical axis

 

 

 

 

12 m at )/–2 m distance from the optical axis

 

 

 

Signaling contacts

Limit values of the relay

 

 

 

 

maximum switching power

30 W

 

 

 

Maximum switching voltage

30 V DC

 

 

 

Maximum switching current

1.0 A

Table 3:

Technical Specifications of the PROFIBUS ILM

 