Siemens SIMATIC NET PROFIBUS manual Sienopyr Duplex Fiber-Optic Marine Cable

Models: SIMATIC NET PROFIBUS

1 490
Download 490 pages 10.94 Kb
Page 218
Image 218

Passive Components for Electrical Networks

7.3.4SIENOPYR Duplex Fiber-Optic Marine Cable

Copper wire

Insulation

Optical fiber

Strain relief

Protective sleeve

Winding

Copper braid

Common jacket

Outer jacket

Figure 7-8Structure of the SIENOPYR Duplex Fiber-Optic Marine Cable

SIENOPYR Duplex Fiber-Optic Marine Cable 6XV1 830–0NH10

The SIENOPYR duplex fiber-optic marine cable contains two multimode graded fibers 62.5/125 m. The cable also contains two stranded, rubber-insulated copper wires with a 1 mm2 cross-sectional area. These can be used, for example, to supply power to the attached devices.

The round cross-section of the cable makes it easier to seal cable glands.

The outer jacket is labeled with the year of manufacture and the label “SIENOPYR-FR MI-VHH 2G 62.5/125 3,1B200+0,8F600+2x1CU 300V” at intervals of approximately 50 cm.

Properties

The SIENOPYR duplex fiber-optic marine cable has the following properties:

SOzone proof complying with DIN VDE 0472 Part 805 test type B

SBehavior in fire complying with IEC 60332-3 cat. A

SCorrosivity of combustion gases complying with IEC 60754-2

SSmoke density complying with IEC 61034

SFree of halogens

SApproved for ship building (Germanischer Lloyd, Lloyd’s Register, Registro Italiano Navale).

7-22

PROFIBUS Networks SIMATIC NET

6GK1970-5CA20-0AA1 Release 2 05/2000

Page 218
Image 218
Siemens SIMATIC NET PROFIBUS manual Sienopyr Duplex Fiber-Optic Marine Cable