TABLE 5-2.

TABLE 5-1Voltage Sensor Thresholds

 

 

 

ADM1026 Generated

 

 

 

 

 

Critical Warning

H8 Initiated Shutdown

Sensor

Sensor

 

(approx.

7%)

(approx. 10%)

 

 

 

 

 

 

Number

Name

Voltage

Lower

Upper

Lower

Upper

 

 

 

 

 

 

 

7

12.0V

12V

11.16V

12.84V

11V

13.2V

8

5.0V

5V

4.8V

5.2V

4.78V

5.23V

9

3.3V

3.3V

3.07V

3.53V

3V

3.6V

10

3.3V STBY

3.3V

3.07V

3.53V

2.97V

3.63V

11

3V VBAT/STBY

3V

2.79V

No UC

no

no

 

 

 

 

 

shutdown

shutdown

12

1.0V

1V

0.93V

1.07V

0.9V

1.1V

13

1.1V CPU

1.1V

1.02V

1.18V

0.99V

1.21V

14

VDD 1.1V

1.1V

1.02V

1.18V

0.99V

1.21V

15

1.5V

1.5V

1.4V

1.61V

1.35V

1.65V

16

VDD 1.8V

1.8V

1.67V

1.93V

1.62V

1.98V

17

VDD 2.5V

2.5V

2.37V

2.68V

2.36V

2.75V

18

VDD_IO 1.2V

1.5V

1.4V

1.61V

1.35V

1.65V

 

 

 

 

 

 

 

Temperature Monitoring

The ADM1026 also monitors the CPU diode temperature on the Netra CP3260 blade server. The ADM1206 and H8 firmware reports a minor, major, or critical alarm when the temperature of the CPU goes beyond the thresholds listed in

Also, if the temperature of the CPU goes beyond the Emergency H8 Shutdown value listed in TABLE 5-2, the H8 initiates a event/warning blade server to the shelf manager and shuts down.

TABLE 5-2CPU Temperature Alarms

Sensor

Sensor

Minor Alarm

Major Alarm

Critical Alarm

Emergency

Number

Name

(UNC)

(UC)

(UNR)

H8 Shutdown

 

 

 

 

 

 

4

CPU Temp 1

>80° C

>90° C

> 102° C

> 102° C

5

CPU Temp 2

>80° C

>90° C

> 102° C

> 102° C

6

Board Temp

>60° C

>70° C

> 88° C

> 88° C

 

 

 

 

 

 

5-16Netra CP3260 Blade Server User’s Guide • April 2009

Page 116
Image 116
Sun Microsystems CP3260 manual 1Voltage Sensor Thresholds, 2CPU Temperature Alarms