2.5.1.1To Remove FB-DIMM Memory Modules

You might need to remove a FB-DIMM module from the Netra CP3260 blade server if you are returning the FB-DIMM module or the blade server for service, or if you are replacing a module with another FB-DIMM module.

Note – Safely store the original factory-shipped FB-DIMM and related FB-DIMM packaging. You might wish to store any removed FB-DIMM in the new FB-DIMM packaging, or use the packaging for service.

To remove a FB-DIMM from the Netra CP3260 blade server, perform the following steps:

1. Take antistatic precautions: attach and electrically ground the wrist strap.

Caution – Always wear a grounded antistatic wrist strap when handling modules.

2.Place the Netra CP3260 blade server on an antistatic mat, or on the blade server’s antistatic bag if you do not have a mat available.

3.For the FB-DIMM you wish to remove, simultaneously pull both FB-DIMM retainer clips outward from the slot (see in FIGURE 2-2).

4.Grasp the FB-DIMM by the edges, and carefully pull it out of its connector (see in FIGURE 2-2). A slight rocking motion might be required.

Caution – Take extra care to prevent damage when removing the outer most FB-DIMMs.

5. Place it in an antistatic bag.

2-10Netra CP3260 Blade Server User’s Guide • April 2009

Page 46
Image 46
Sun Microsystems CP3260 manual To Remove FB-DIMM Memory Modules