5.2.10ATCA Power Module (−48V to 12V)

The Netra CP3260 blade server uses the Artesyn ATCA power module solution. The Artesyn power module provides an integrated ATCA power solution that meets PICMG 3.0 requirements, including dual bus input, DC isolation, hold up, hot-plug, and management power (3.3V standby). It provides a 12V intermediate bus as backend power. Some of the salient features of the module are:

210 watts output power.

Input-to-output isolation.

12V with current rating of 17.5A.

3.3V standby at 1.82A. (The IPMC draws power from IPMI Power (3.3V_STBY) so it can remain functional even if back-end logic is powered down.)

Isolated remote ON/OFF.

Isolated “A” and “B” bus detect signals.

High efficiency, typically 88 percent.

Operating input voltage: −39V to −72V.

The I2C interface monitors the status of fuse, input voltages, output voltages, and temperature and sends an alarm if any of the parameters are outside the programmable threshold.

FRU information.

5.2.11TOD Clock Battery

The TOD clock battery must be type CR1632, with a minimum of 4ma abnormal charging current rating (for example; a Renata CR1632).

Caution – Risk of explosion if battery is replaced by an incorrect type.

Dispose of batteries properly in accordance with manufacturer’s instructions and local regulations.

See Section 2.5.3, “Adding or Replacing TOD Clock Battery” on page 2-14 for battery location and installation instructions.