Sun Microsystems CP3260 manual Features

Models: CP3260

1 144
Download 144 pages 25.13 Kb
Page 20
Image 20
1.2Features

Elimination of PCI connectivity between the blade servers in the system and reallocation of connectivity to serial interconnects, eliminating single points of failure

Mandatory use of Intelligent Platform Management Interface (IPMI) management interfaces

Flexible user I/O

Power and thermal management guidelines enforced by the management infrastructure

Separation of control and data traffic by supporting the Base (PICMG 3.0) and Fabric (PICMG 3.1) interfaces

The ATCA standard consists of the PICMG 3.0, PICMG 3.1, PICMG 3.2, and PICMG

3.3 specifications. The Netra CP3260 blade server complies with:

PICMG 3.0, the base specification that defines the mechanical, power distribution, system management, data transport, and regulatory guidelines

PICMG 3.1, which builds upon the PICMG 3.0 base specification and the IEEE 802.3-2003 standard

1.2Features

TABLE 1-1provides a summary of Netra CP3260 features.

TABLE 1-1Netra CP3260 Blade Server Feature Summary

Feature

Description

 

 

CPU

• One UltraSPARC T2 processor (6 or 8 cores, 8 threads/core)

 

• CPU core speed: 1.2 GHz

Memory

Fully-Buffered DDR2-based memory DIMMs (FB-DIMMs)

 

• Eight FB-DIMM slots (one per channel or two per memory controller)

 

1-Gbyte or 2-Gbyte FB-DIMMs, for a total memory of 16 Gbytes

Service

• Service processor (MPC885) for CPU reset, boot, partition, and fault

processor

management architecture (FMA)

Power

• 200 watts maximum

requirement

• Dual redundant input 48V to derive on-board power

Cooling

• 32 - 35 cfm at 55C

requirement

 

 

 

1-2Netra CP3260 Blade Server User’s Guide • April 2009

Page 20
Image 20
Sun Microsystems CP3260 manual Features