2.7Installing the Netra CP3260 Blade Server
Caution – The Netra CT 900 server fan tray upgrade kit
To verify that the fan tray upgrade is installed on a Netra CT 900 server, log into the Shelf Manager and issue the following command for fan trays 1, 2, and 3 (or fan trays 0, 1, and 2 for older chassis):
clia fruinfo fan_tray 1 grep "Product Part"
If Product Part / Model Number =
To Install the Netra CP3260 blade server, perform the following steps:
1.If you have installed a Netra CP32x0 ARTM, go to the front of the system and locate the card slot where you installed the ARTM at the rear of the system.
2.Remove the filler panel, if necessary.
The filler panel is secured to the card cage using two screws, one at the top of the filler panel, the other at the bottom. Store the filler panel in a safe place; you might need to use it again if you have to remove a card for an extended period of time.
3.Prepare the blade server by opening the injector/ejector latches (FIGURE
4.Carefully align the edges of the blade server with the card guides in the appropriate slot (FIGURE
It might be helpful to look into the enclosure to verify correct alignment of the rails in the guides.
5.Taking care to keep the blade server aligned in the guides, slide the blade server in until the injector/ejector latches engage the card cage.