Sun Microsystems CP3260 manual 2 I/O Configurations, ATCA chassis midplane

Models: CP3260

1 144
Download 144 pages 25.13 Kb
Page 31
Image 31
1Sun Netra CP3260 blade server

Figure Legend

1Sun Netra CP3260 blade server

2Sun Netra CP32X0 ARTM

3ATCA chassis midplane

Note – When a Netra CP32x0 ARTM is used with the Netra CP3260 blade server, shielded cables are required for serial I/O ports. Unshielded cables can be used on Ethernet ports to satisfy EMI compliance standards. The shields for all shielded cables must be terminated on both ends.

The customer can order a Netra CP32x0 ARTM, build a custom card, or buy from an independent hardware vendor (IHV). A minimal set of I/O must provide a boot path for the host blade server and a path for console I/O to deliver commands and to read blade server and system status.

Possible boot and console configurations are described in TABLE 1-2. Sun Microsystems supplies the Netra CP3260 blade server and compatible Netra CP32x0 ARTMs. The other configurations require (IHV) hardware.

TABLE 1-2I/O Configurations

I/O

Hardware Required

Description

 

 

 

Ethernet

Netra CP3260 blade server

 

Netra CP32x0 ARTM

 

(ARTM—supplied as an option

 

for rear access)

Default boot path uses the Ethernet port; when the blade server runs in diskless client configuration.

SAS

Netra CP32x0 SAS Storage

SAS devices can be used for local booting.

 

ARTM, Dual HD

 

Serial data

Netra CP3260 blade server

Serial port on front panel provides a path for a console I/O.

 

Netra CP32x0 ARTMs

The serial port can be used on either the Netra CP3260 blade

 

 

server or Netra CP32x0 ARTM, but both ports cannot be used at

 

 

the same time. If the serial port on Netra CP3260 blade server is

 

 

used, the serial port on the Netra CP32x0 ARTMs should not be

 

 

used and vise versa.

Compact

Sun Compact Flash card

The Compact Flash connector can be used to add an optional

Flash

 

Sun 8-Gbyte or 16-Gbyte user flash type I/II memory card.

 

 

 

Chapter 1 Introduction 1-13

Page 31
Image 31
Sun Microsystems 2 I/O Configurations, Sun Netra CP3260 blade server 2 Sun Netra CP32X0 ARTM, ATCA chassis midplane