Tally T8006e Color Laser Printers User Guide

8. Install the new waste toner pack.

9. Close the front cover by carefully push- ing it inward until it locks.

Replacing the Fuser Cleaning Roller

Replace the fuser cleaning roller at least once every 12 months, or when the control panel display indicates that replacement is necessary. The life of the fuser cleaning roller in the T8006e is about 12,000 pages (at a 5% toner coverage rate on letter-size paper).

Warning! Make sure the power switch is off, and that the printer has cooled for a minimum of 30 minutes before replacing supplies near the fusing unit.

Caution! Always replace the ozone filter when you replace the fuser cleaning roller.

1. Turn off the power switch.

66

Page 74
Image 74
Tally Genicom T8006e manual Replacing the Fuser Cleaning Roller