Basic Measurements
1760 SeriesComponent Waveform/Vector Monitor User Manu al
4-16
Lightning Meas urements
The Lightning display gives indication of absolut e and rela-
tive amplitudesand relative timing of the three components.
For a Lightning display, apply color-difference signals (Y, PB
and PR) to the rear panel CH-A1, A2, and A3 (or CH-B1, B2,
and B3) connectors. Push the front-panel LIGHTNING button.
The instrument is forced to A123 input display (it can be
changed to B123).
Use the CONFIG—FORMAT menu (page 3-21) to set DISPLAY
to LIGHTNING, and select the appropriate format for your
system. Lightning is most useful in the color difference for-
mats: SMPTE, EBU, BETA, and MII. (Selecting GBR will pro-
vide a square display.) Usethe CONFIG—VECTOR menu to
select 75% or 100% bars. This will change the size of the
electronic graticule to accommoda te the input signal. Push
CLEAR MENU to clear the menu readout.
Channel 2 is comparedto Channel 1 in the top half of the
display; Channel3 is compared to Channel 1 in the lower
half. (See Figure 4-14.)
525/60
C
M
B
R
M
C
G
B
R
G
YL
Y
L
White
Black
Setup
White
Figure 4-14. Lightning display showing correcttiming.