Functional Overview
1760 SeriesComponent Waveform/Vector Monitor User Manu al
3-6
OverlayOVERLAYsuperimposes the selected input signals. In OVER-
LAYmode, the LINE/FIELD button remains a four-way toggle,
providing one line, two line, one field, a nd two field dis-
plays.
SweepSweep buttons are used to select the waveform sweep rate.
LINE/FIELDtoggles through four sweep ra te selections: one
line, two line, onefield, and two field. In PARAD E mode, the
LINE/FIELDbutton becomes a two-way switch, togglingbe-
tween line and field.
The sweep rate is displayed in the upper right corner of t he
CRT(for field-rate sweeps, 1 F or 2 F is displayed).
The MAG buttonis used with LINE/FIELD to provide horizontal
magnification ofeach rate as follows:
HOne line magnified = 200 ns/division
HTwo line magnified = 1 ยตs/division
HOne field or two field magnified = approxim ately
X20 magnification.