OperatorsCheckout P rocedure
1760 SeriesComponent Waveform/Vector Monitor User Manu al
2-22
9. Line Selection
Line select is availablein WAVEFORM, VECTOR, SCH,and
PICTURE display modes. Enter the LINE SELECT menu and
turn the centerbezel control until the readout displays ALL
131. Ina twoline display, line 131 appearson the left,
followed by line 132.
Select 2FIELDsweepand note the intensified line in each
field. Select15H and note that 15 lines are now intensified
in each field (intensifiedportion appears wider). The
readout is now ALL 131---- 145. See Figure 2-13.
Select 1of2. Now only the first field has intensified line s,
and a NEXT FIELD selection appears. Select NEXT FIELD and
note that the intensified lines now appear onl y in the second
field and the readout is F2 131 F2 145.
Select MULTIPLEwith WAVEFORM, VECTOR, and SCH. Note
that the displaysappear in the following order: WAVEFORM,
VECTOR, SCH.
Exit the line select menu. Enter the m enu again and note
that the user settings are unchanged. Exit the menu.
LINE SEL
ALL131 FIELD
ALL 1OF2
1OF81OF4
1H
15H
-- -- 1 4 5