1760 SeriesComponent Waveform/Vector Monitor User Manu al 2-11
Operator’s CheckoutProcedure
Before proceeding, read At A Glance startingonpage2-1.
This procedureis designed for operator familiarization and
for checkingbasic instrument operation (not measurement
quantities or specifications). All illustrations are of the 1765
unless otherwise noted.
If performing this procedure reveals im proper instrument
operation, first check the operation of the associated equip-
ment. If the associated equi pment is operating normally,
refer the 1760--Series to qualified service personnel for
repair or adjustment.

Required Equipment

The following equipment is required to perform thi sproc e-
dure:
1. Television Signal G enerator with:
CompositeColor Bars
Component signal (Y,B --Y,R--Y)
Channel Timing(Bowtie)
Black Burst or comparable signal with burst and sync.
For example: TEKTRONIXTSG 130--SeriesMultifor-
mat Signal Generator
2. Coaxial Cable, 75(5)
For example: 42-inch RG59U (Tektronix Part No.
012-0159-00)
3. 75Terminators, End-lin e (4)
For example: (Tektronix Part No. 011-0102-00)