INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

(Revision Date: Jan. 19, 2006)

2. Strip Module

13.Press the [PAUSE] key repeatedly until “P.P.FEED” appears on the LCD.

14.Press the [FEED] key to feed a label for checking the next label’s stop position. If the next label stops with its top edge aligning with the strip shaft edge, an adjustment is not required. Go to Step 15.

Continued.

PAUSE

<2>PARAMETER SET

P.P.FEED +0.0mm

PAUSE

A label is fed.

If not, press the [RESTART] key to return to “P.P.FEED +0.0mm” display, and adjust the pre-strip amount. Set the value in a range from +9.9 to 2.5 with the [FEED] or [RESTART] key.

The next label stops with its top edge aligning with the strip shaft edge.

FEED

Check the next

label’s stop

position

The next label stops with its top edge misaligning with the strip shaft edge.

RESTART

When the top edge of the label stops past the strip shaft edge, set a negative () value.

Top edge of the label

Manual backgroundStrip Shaft Edge

When the top edge of the label stops short of the strip shaft edge, set a positive (+) value.

Top edge of the label

Manual background Strip Shaft Edge

15.When the adjustment is completed, press the [PAUSE] key twice to finish the setting.

<2>PARAMETER SET P.P.FEED +0.0mm

 

 

 

 

 

 

 

 

+9.9mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+9.8mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

RESTART

:

 

 

 

 

+0.1mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+0.0mm

 

 

 

 

FEED

-0.1mm

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

-2.4mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-2.5mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

 

 

 

 

<2>PARAMETER SET BACK SPEED STD

Turn the power OFF.

16.Send an issue command to the printer and check for proper strip issue.

Turn the power ON.

Label issue