Toshiba B-SA4T Installation Procedure For Optional Equipment, +99 99mm Reverse feed, +00 Default

Models: B-SA4T

1 58
Download 58 pages 37.75 Kb
Page 54
Image 54
+99 (99mm) Reverse feed

INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

(Revision Date: Feb. 25, 2008)

8. RFID Module: B-SA704-RFID-U2-EU-R

Continued from the

previous page

<10>RFID

ADJ RETRY +00

[PAUSE]

<10>RFID

POWER LEVEL 18

[PAUSE]

<10>RFID

AGC THRESHOLD 0

[PAUSE]

<10>RFID

RF CHANNEL AUTO

[PAUSE]

RFID adjustment for retry menu is displayed.

If writing data on a tag failed, the printer feeds the RFID tag forward or backward for specified length in order to retry writing data. When “0” is set for this parameter, this function and a retry are not performed.

Only the value of –3mm or less or +3mm or more becomes effective.

Set a value to move the RFID tag position with the [FEED] or [RESTAT] key.

 

 

 

 

 

+99 (99mm) Reverse feed

 

 

 

 

 

 

[RESTART]

 

 

 

 

 

 

 

 

 

 

 

+00 (Default)

 

 

 

 

 

 

 

[FEED]

 

 

 

 

 

 

 

 

 

-99 (-99mm) Forward feed

 

 

 

 

 

Press the [PAUSE] key.

Radio output power level setting menu is displayed.

When the value is “9”, the power is the weakest, and when “18”, the power is the strongest. The factory default setting is “18”. The optimum value differs depending on the tag types. Usually, it is not necessary to change this value but changing the value may be able to increase the number of successful read/write times.

Set the power level with the [FEED] or [RESTART] key.

 

 

 

 

 

18 (Default, Strongest)

 

 

 

 

 

 

 

 

 

 

 

[RESTART]

 

 

 

 

 

 

 

 

 

 

 

 

 

[FEED]

 

 

 

 

 

 

9 (Weakest)

Press the [PAUSE] key.

AGC threshold setting menu is displayed.

When the obtained gain of an RFID tag is lower than the AGC threshold, the tag is considered as an error tag even if a data write succeeds.

When the AGC threshold is set to “0”, all tags are writable.

When set to “8”, for example, only tags with the AGC threshold level of 9 or greater are writable. The optimum value is different depending on the tag types. The factory default is 0. Set an AGC threshold with the [FEED] or [RESTART] key.

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

[RESTART]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[FEED]

 

 

 

 

 

 

 

 

 

0 (Default)

 

 

 

 

 

 

Press the [PAUSE] key.

RFID channel setting menu is not available to the B-SA704-RFID-U2-EU-R.

Press the [PAUSE] key to skip this menu.

Continued to the next page.

8- 14

Page 54
Image 54
Toshiba B-SA4T Installation Procedure For Optional Equipment, +99 99mm Reverse feed, +00 Default, 99 -99mm Forward feed