INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
(Revision Date: Feb. 25, 2008)
8. RFID Module:
Continued from the previous page
3132333435363738
39304142 (0A)
[FEED], [RESTART]
<10>RFID
Read data is displayed.
Data in parentheses ( ) is the AGC value expressed in hex. code. Write down this value.
Press the [FEED] and [RESTART] keys to return to the RFID Setting Menu (”<10>RFID”).
3)Set an AGC threshold of data write.
Set a value which is lower than the AGC value obtained by a read test by 1 or 2, taking variation of RFID tags in performance into consideration.
Example
<10>RFID
[PAUSE]
<10>RFID |
|
Q VALUE | 2 |
[FEED] or [RESTART]
<10>RFID |
|
Q VALUE | 2 |
When ”<10>RFID” is displayed, press the [PAUSE] key until the Q value setting menu is displayed.
Choose “2” with the [FEED] or [RESTART] key.
When “2” is already chosen, go to the AGC threshold for data write setting menu.
|
|
| 15 |
|
|
| • |
| [RESTART] | ||
| • | ||
|
|
| |
|
|
| 2 (Default) |
| [FEED] | • | |
|
|
| • |
|
|
| 0 |
[PAUSE]
<10>RFID |
|
WT AGC | 11 |
[FEED] or [RESTAT]
<10>RFID |
|
| ||
WT AGC | 9 |
| ||
|
|
|
| |
| [PAUSE] |
| ||
|
|
|
|
|
|
|
| ||
<10>RFID |
|
| ||
WT MIN AGC | 11 |
[FEED] or [RESTAT]
<10>RFID
WT MIN AGC 9
[PAUSE]
<10>RFID
Press the [PAUSE] key.
AGC threshold for data write setting menu is displayed.
Choose a threshold value (decimal number) with the [FEED] or [RESTART] key.
When the measured AGC is 10 (0A), for example, choose “9” (a value lower than the measured AGC by 1 or 2).
|
|
|
|
| 15 |
|
|
|
|
| • |
| [RESTART] | ||||
| • | ||||
|
|
|
|
| 11 (Default) |
|
| [FEED] |
| • | |
|
|
| • | ||
|
|
|
|
| |
|
|
|
|
| 0 |
|
|
|
|
|
Press the [PAUSE] key.
AGC threshold lower limit for retry setting menu is displayed. Choose a lower limit (decimal number) with the [FEED] or [RESTART] key.
Usually, choose the same value with the AGC threshold for data write (WT AGC).
|
| 15 |
|
| • |
[RESTART] | • |
|
| 11 (Default) |
|
| |
|
| • |
[FEED] | • | |
|
| 0 |
|
|
Press the [PAUSE] key.
RFID Setting Menu (”<10>RFID”) is displayed.
An AGC threshold setting is completed.
8- 17