100°

INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

2. Strip Module

2.Open the Front Cover wider. Remove the Front Cover by lifting it to disengage the hinge pins from the hinge. The Front Cover cannot be removed unless it is opened at an angle of over 100 degrees as the stoppers of the hinge prevent disengagement.

100°

Front Cover Hinge

Manual backgroundHingeStopper

3. Mount the strip Module Cover by inserting the hinge pins into the hinges.

Hinge

Strip Module Cover

Hinge

4. Fit the Shaft Holders of the Backing Paper Feed Roller into the cuts of the printer.

Shaft Holder

Cut

Cut

Strip Unit

Backing Paper Feed Roller

2- 9