INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

(Revision Date: Jan. 19, 2006)

6. Real Time Clock: B-SA704-RTC-QM-R

 

 

(Continued from the

 

 

 

 

 

10. Pressing the [PAUSE] key enables setting the

previous page)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hour.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

11. Set the Hour with the [FEED] or [RESTART]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<8>RTC SET

 

 

 

 

 

 

key. Pressing the [PAUSE] key fixes the Hour

 

 

 

 

 

 

 

 

FEED

 

RESTART

and cause the cursor to move to the Minute.

TIME H

00/00/00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12. Set the Minute with the [FEED] or [RESTART]

Hour

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

key.

Pressing the [PAUSE] key fixes the

 

 

 

 

 

 

 

 

 

 

 

Minute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minute and cause the cursor to move to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<8>RTC SET

 

 

 

 

 

 

 

 

 

Second.

 

 

 

 

 

FEED

 

RESTART

TIME M

10/00/00

 

 

 

 

 

13. Set the second with the [FEED] or [RESTART]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

key. Press the [PAUSE] key to fix the Second.

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

Then, the Low Battery Check selection screen

 

 

 

 

 

 

 

 

 

 

 

Second

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<8>RTC SET

 

 

 

 

 

 

 

 

 

 

 

FEED

 

RESTART

14. Pressing the [PAUSE] key enables choosing

TIME S

10/30/00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

whether to activate the low battery check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

function or not. Set the function to ON or OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with the [FEED] or [RESTART] key.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<8>RTC SET

 

 

 

 

 

 

ON:

Low battery check function is activated.

 

 

 

 

 

 

LOW BATT. CHECK

 

 

 

 

 

 

OFF: Low battery check function is not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

activated. (Default)

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

Press the [PAUSE] key to fix the setting. Then,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the RTC Data Renewal Timing setting screen is

<8>RTC SET

 

 

 

FEED

 

RESTART

displayed.

LOW BATT. OFF

 

 

 

 

 

 

 

 

 

 

 

15. Pressing the [PAUSE] key enables choosing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

the RTC data renewal timing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16. Choose PAGE or BATCH with the [FEED] or

<8>RTC SET

 

 

 

 

 

 

[RESTART] key.

RENEWAL

 

 

 

 

 

 

PAGE:

A real time can be printed on each

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

media. However, the printer needs to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stop the motion before printing each

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<8>RTC SET

 

 

 

 

 

 

 

media to read the real time clock data.

 

 

 

FEED

 

RESTART

BATCH: Batch print is possible. However, the

RENEWAL BATCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

same time is printed on the all media

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

issued in a batch because the real

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

time clock data is read only for the first

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

media.

<8>RTC SET

 

 

 

 

 

 

Press the [PAUSE] key to fix the setting. Then,

DATE

06/03/01

 

 

 

 

 

 

 

the current date is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEED

 

 

RESTART

 

 

17. Press the [FEED] and [RESTART] keys at the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

same time to return to “<8>RTC SET” display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<8>RTC SET

 

 

 

 

 

 

 

 

 

 

 

 

<Supplementary Explanation>

1.Be sure to load the battery and set the low battery check function to ON whenever the real time clock is used. If the battery is not loaded or the battery voltage is low, the real time clock data is erased at the power off time.

2.When the low battery check function is set to ON and if the battery voltage is 2.4V or less, the printer will result in a “LOW BATTERY” error and stop at the power on time. In that case, hold down the [RESTART] key to restore to “<1>RESET” display.

3.When “LOW BATTERY” error has occurred, contact the nearest TOSHIBA TEC service representative for replacement of the battery.

4.If you would like to keep using the same battery even after “LOW BATTERY” error occurs, set the Low battery check function to OFF, and set the date and time to the real time. As long as the power is on, the Real Time Clock will function. However, once the power is turned off, the date and time will be reset. Then, please ask for the battery replacement.

6- 6

Page 37
Image 37
Toshiba B-SA4T installation manual With the Feed or Restart key