STE 58760
iii
NOTE!
FOR EUPOREAN UNION (EU)
In European Union (EU), there are following limitations and notes to approve the
CE Marking EMC Direction. In other countries and areas, it is not necessary to
apply to these limitations and notes.
(1) Set up conditions
The following type of power line transformer must be used.
Frequency: 50 or 60 Hz
Secondary voltage: 3 phase 200 ~ 230 VAC
power capacity: Min. 2.7 kVA
(2) Input power condition
Core wires: 3.5 mm2 ~ 5.5 mm2
Voltage short interruption: 0.5 cycle
(3) Ground
Core wires: 0.08 mm2 ~ 0.5 mm2
Ground condition: Exclusive ground line for robot ground impedance
must be less than 100 Ω.
(4) Ex ternal input and output line / Optional input and output line
Core wires: 0.08 mm2 ~ 0.5 mm2
Shield: Ground shield
Cable length: Max. 10 m
Manufacturing method: Refer to figure A.
Signal ground: Voltage potential between signal ground PGBA and
controller frame ground F.G. must be the same.
(5) Serial communication line
Only 1 of 4 serial communication ports (connector name; J1 ~ J4) can be us ed at
the same time.
Core wires: 0.08 mm2 ~ 0.5 mm2
Shield: Ground shield
Cable length: Max. 10 m
Twisted pair: Not required for RS-232C, required for RS-422.
Manufacturing method: Refer to figure A.