0.08 mm2 ~ 0.5 mm2 Ground shield Max. 10 m
Not required for RS-232C, required for RS-422. Refer to figure A.

STE 58760

NOTE!

FOR EUPOREAN UNION (EU)

In European Union (EU), there are following limitations and notes to approve the CE Marking EMC Direction. In other countries and areas, it is not necessary to apply to these limitations and notes.

(1)Set up conditions

The following type of power line transformer must be used.

Frequency:

50 or 60 Hz

Secondary voltage:

3 phase 200 ~ 230 VAC

power capacity:

Min. 2.7 kVA

(2) Input power condition

 

Core wires:

3.5 mm2 ~ 5.5 mm2

Voltage short interruption: 0.5 cycle

(3)Ground

Core wires:

0.08 mm2 ~ 0.5 mm2

Ground condition:

Exclusive ground line for robot ground impedance

 

 

must be less than 100 Ω.

(4) External input and output line / Optional input and output line

Core wires:

0.08 mm2 ~ 0.5 mm2

Shield:

Ground shield

Cable length:

Max. 10 m

Manufacturing method:

Refer to figure A.

Signal ground:

Voltage potential between signal ground PGBA and

 

 

controller frame ground F.G. must be the same.

(5)Serial communication line

Only 1 of 4 serial communication ports (connector name; J1 ~ J4) can be used at

the same time. Core wires: Shield:

Cable length: Twisted pair:

Manufacturing method: