The UCF template is provided for designs that target the ML605. Net names provided in the constraints below correlate with net names on the ML605 Rev. D schematic. On identifying the appropriate pins, the net names below should be replaced with net names in the user RTL. See the Constraints Guide for more information.

Users can refer to the UCF files generated by tools such as MIG (Memory Interface Generator for memory interfaces) and BSB (Base System Builder) for more detailed information concerning the I/O standards required for each particular interface. The FMC connectors J63 and J64 are connected to 2.5V Vcco banks. Because each user’s FMC card implements customer-specific circuitry, the FMC bank I/O standards must be uniquely defined by each customer.

NET "CLK_33MHZ_SYSACE"

LOC = "AE16";

## 93

on U19

NET "CPU_RESET"

LOC = "H10";

## 2

on SW10 pushbutton (active-High)

##

 

 

 

NET "DDR3_A0"

LOC = "L14";

## 98

on J1

NET "DDR3_A1"

LOC = "A16";

## 97

on J1

NET "DDR3_A2"

LOC = "B16";

## 96

on J1

NET "DDR3_A3"

LOC = "E16";

## 95

on J1

NET "DDR3_A4"

LOC = "D16";

## 92

on J1

NET "DDR3_A5"

LOC = "J17";

## 91

on J1

NET "DDR3_A6"

LOC = "A15";

## 90

on J1

NET "DDR3_A7"

LOC = "B15";

## 86

on J1

NET "DDR3_A8"

LOC = "G15";

## 89

on J1

NET "DDR3_A9"

LOC = "F15";

## 85

on J1

NET "DDR3_A10"

LOC = "M16";

## 107

on J1

NET "DDR3_A11"

LOC = "M15";

## 84

on J1

NET "DDR3_A12"

LOC = "H15";

## 83

on J1

NET "DDR3_A13"

LOC = "J15";

## 119

on J1

NET "DDR3_A14"

LOC = "D15";

## 80

on J1

NET "DDR3_A15"

LOC = "C15";

## 78

on J1

NET "DDR3_BA0"

LOC = "K19";

## 109 on J1

NET "DDR3_BA1"

LOC = "J19";

## 108

on J1

NET "DDR3_BA2"

LOC = "L15";

## 79

on J1

NET "DDR3_CAS_B"

LOC = "C17";

## 115

on J1

NET "DDR3_CKE0"

LOC = "M18";

## 73

on J1

NET "DDR3_CKE1"

LOC = "M17";

## 74

on J1

NET "DDR3_CLK0_N"

LOC = "H18";

## 103 on J1

NET "DDR3_CLK0_P"

LOC = "G18";

## 101 on J1

NET "DDR3_CLK1_N"

LOC = "L16";

## 104 on J1

NET "DDR3_CLK1_P"

LOC = "K16";

## 102

on J1

NET "DDR3_D0"

LOC = "J11";

## 5

on J1

NET "DDR3_D1"

LOC = "E13";

## 7

on J1

NET "DDR3_D2"

LOC = "F13";

## 15

on J1

NET "DDR3_D3"

LOC = "K11";

## 17

on J1

NET "DDR3_D4"

LOC = "L11";

## 4

on J1

NET "DDR3_D5"

LOC = "K13";

## 6

on J1

NET "DDR3_D6"

LOC = "K12";

## 16

on J1

NET "DDR3_D7"

LOC = "D11";

## 18

on J1