Upper Housing /Wireless Modules-QL220 & QL 220 Plus

You must use an ESD strap and work at a properly grounded workstation (antistatic mat or tray). All electronic components must be placed on an ESD protective tray. If stored, any elec- tronic components must be placed in antistatic bags.

The following pages detail the procedure to install the Cover used for non-wireless units and the following Wireless wireless modules:

Module Type

QL 220

QL 220+

Module Housing (no wire- less)

IrDA Module Bluetooth 1.2 (B/C) Bluetooth 2.0 (D)

Compact Flash 802.11b (EU countrys) “N” option

Compact Flash 802.11b (North America) “M” option

802.11b SRRF “F” Opt.ion

802.11g SRRF “K” Option

AN16972-019

n/a RK18237-1

RK18239-1

RK18238-1

n/a

n/a

RK17735-027

RK17735-025 RK17735-021 RK18879-001

RK17735-022

RK17735-023

RK17735-024 RK17735-026

Tools Needed

3/32” Hex Driver

Removing the Upper Housing

1.Turn the printer off and remove the Battery.

2.Remove the Upper Housing or Wireless Module by removing (3) screws on the bottom cover. Retain all hardware and either the “D” rings or the Carrying Strap supplied with the printer.

“D” Ring

Upper Housing or

 

Wireless Module

“D” Ring

Screw, #4-40 x 1 1/4” (2)

Screw, #4-40 x 3/16”

continued

2-61

RMAN-QLS-002 rev. A Repair Procedures

Page 38
Image 38
Zebra Technologies Q4DLU1B000000 manual Upper Housing /Wireless Modules-QL220 & QL 220 Plus, Removing the Upper Housing