Connector Door, QL 220 /QL220 Plus - AN16972-021

You must use an ESD strap and work at a properly grounded workstation (antistatic mat or tray). All electronic components must be placed on an ESD protective tray. If stored, any elec- tronic components must be placed in antistatic bags.

Tools needed

3/32” Hex Driver

Remove the Lower Cover

1.Turn the printer off and remove the battery pack.

2.Remove the Lower Housing

Remove the Upper Housing by removing (3) Screws and pulling the upper housing clear.

Remove the two screws from the Printer Frame.

Pivot the Lower Cover away from the printer chassis until the Connector Door is free.

Remove the Connector Door

Pull the Connector Door away from the Printer Frame.

Attach the new Connector Door

Press the Door, Connector, Rubber over the retaining feature on the bottom of the Printer Chassis Assembly as shown.

Re-assemble the Lower Housing to the Printer Frame.

Printer shown with Lower Housing removed

QL220 Door, Connector, p/n CA16548-1

2-81

RMAN-QLS-002 rev. A Repair Procedures

Page 58
Image 58
Zebra Technologies Q4DLU1B000000, Q3DLUBA000002 Connector Door, QL 220 /QL220 Plus AN16972-021, Remove the Lower Cover