tom of the Printer Frame.

4.Plug the Bar Sensor Cable into J2 (BAR) on the MLB and lock the connector.

5.Install the Printer Chassis in the Lower Housing.

6.If necessary, install the Platen and Gear.

7.Install the Upper Housing.

8.Calibrate the Sensors.

This procedure can only be performed by Zebra certified personnel using special equipment and software.

Using the gray and white swatches, follow the on-screen instructions on the unit test and set-up software to properly calibrate the sensors. It is recommended that the complete unit test procedure be performed.

RMAN-QLS-002 rev. A Repair Procedures

2-44

Page 21
Image 21