cables are locked.

11.Assemble the Upper Housing to the Printer, and secure it with the retained hard- ware. At this time either the “D” rings, or the Carrying strap which was supplied with the printer should be reassembled. Note that the longer screws are used to secure the “D” rings.

6.Install the QuickLink module. Plug the either the QuickLink module or the mod- ule housing supplied with the printer into the Top Housing, and secure with (1) screw through the battery compartment.

7.Install the Battery Pack. Reinstall the Battery Pack and perform a two-key reset to verify that the Printer has been properly reassembled.

8.Perfom the Unit Test procedure. Perform a complete unit test to ensure that the sensor calibrations are still correct, and the motor is operating correctly.

4 3

 

5

5

5

 

 

5

J3

J4

 

J10

 

 

 

J5

J11

 

 

 

 

J2

From

# of connections

CPU Connector #

 

 

 

Printhead

28 (Flex)

J3

 

 

 

Motor

4

J4

 

 

 

Media Width Sensor (optional)

3

J11 (bottom of board)

Bar Sensor Cable

3 (Flex)

J2

 

 

 

Gap Sensor/Printhead Ground

5 (Flex)

J10

 

 

 

Label Presence Sensor

4 (Flex)

J5

 

 

 

2-85