If PCC digit 10 = S, set SW1 to OTHER CW (turn fully clockwise) (PIM-compati- ble).

5.Install the Keypad cables per the table on the preceding page..

6.Install the Upper Housing and Lower Housing.

Compatibility Switch (SW1).

7.Install the Battery Pack.

8.Load the application. You must reload the printer’s original application files. The application files can either be stored on your local system or can be down- loaded from the factory’s database.

You must have authorization from Zebra to access the application files from the factory.

10.Calibrate the Sensors. Using the gray and white swatches, follow the on-screen instructions on the unit test and set-up software to properly calibrate the sen- sors.

2-101

RMAN-QLS-002 rev. A Repair Procedures

Page 78
Image 78
Zebra Technologies Q4DLU1B000000, Q3DLUBA000002 manual Compatibility Switch SW1