Zebra Technologies Q3DLUBA000002, Q4DLU1B000000 manual Install Label Present Sensor Option

Models: Q3DLUBA000002 Q4DLU1B000000

1 109
Download 109 pages 33.33 Kb
Page 45
Image 45
Insert the Label Pres- ent Sensor Flex Cable into J5 as shown.

Install Label

Present Sensor

Option

Dress the long end of the optional Label Present Sensor Cable

through the Printer Frame so that it emerges

as shown near J5 of the MLB.

Plug the Sensor Cable into J5 of the MLB as shown. The

Sensor Cable flex circuits in- stalls in a zero insertion force (ZIF) connector.

Pull the connector open to insert the flex circuit. After insertion insure the connec-

is closed to properly retain the flex circuit.

Re-install the Upper Housing

1. Assemble the Upper Housing to the Print-

er, and secure it with the retained hardware.

At this time either the “D” rings, or the Carry- ing strap which was supplied with the printer

should be reassembled. Note that the longer

screws are used in the corners of the Upper cover where the “D” rings or the carrying strap was installed.

2.Re-install the QuickLink module. Plug the either the QuickLink module or the module housing supplied with the printer into the Top Housing, and secure with (1) screw through the battery compartment.

3.Install the Battery Pack.

4.Test the printer with the unit test software to properly calibrate the sensor and verify its proper operation.

RMAN-QLS-002 rev. A Repair Procedures

2-68

Page 45
Image 45
Zebra Technologies Q3DLUBA000002, Q4DLU1B000000 manual Install Label Present Sensor Option, Re-install the Upper Housing