1-12  CHAPTER 1: OVERVIEW
Table   | 
  | 
  | 
  | ||
Attribute  | Description  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
Weight  | 12.0 lb (5.5 kg)  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | |
Table   | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
Parameter  | Requirement  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
Input voltage  | 115/230 VAC  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | |
Input voltage ranges  | 90 to 132 VAC  | Either range accepted without user  | 
  | ||
  | or 180 to 264  | switching  | 
  | 
  | |
  | VAC | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | |
Maximum current  | 1.8 A  | Fuse: 3 A, 250 V,   | 
  | ||
consumption  | 
  | 
  | mm  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Maximum power  | 161 W  | 
  | 
  | 
  | |
consumption  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Heat dissipation  | 550 BTU/h  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | |
Table   | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Requirement  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Parameter  | 
  | Minimum  | 
  | Maximum  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Temperature:  | 
  | 
  | 
  | 
  | 
  | 
Operating  | 
  | 41°F (5°C)  | 
  | 104°F (40°C)  | 
  | 
Nonoperating  | 
  | 
  | 140°F (60°C)  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
Altitude:  | 
  | 
  | 
  | 
  | 
  | 
Operating  | 
  | Sea level  | 
  | 15,000 ft. (4,572 m)  | 
  | 
Nonoperating  | 
  | Sea level  | 
  | 40,000 ft. (12,191 m)  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Relative humidity:  | 
  | 
  | 
  | 
  | 
  | 
Operating  | 
  | 20% noncondensing  | 80% noncondensing  | 
  | |
Nonoperating  | 
  | 10% noncondensing  | 90% noncondensing  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
The server power supply has overcurrent protection on the +5 V output and overvoltage protection on +5 V DC. The server’s total power consumption is approximately 161 W maximum.