1-12 CHAPTER 1: OVERVIEW
Table |
|
|
| ||
Attribute | Description |
|
|
| |
|
|
|
|
|
|
Weight | 12.0 lb (5.5 kg) |
|
|
| |
|
|
|
|
| |
Table |
|
|
| ||
|
|
|
|
|
|
Parameter | Requirement |
|
|
| |
|
|
|
|
|
|
Input voltage | 115/230 VAC |
|
| ||
|
|
|
|
| |
Input voltage ranges | 90 to 132 VAC | Either range accepted without user |
| ||
| or 180 to 264 | switching |
|
| |
| VAC |
|
|
| |
|
|
|
|
| |
Maximum current | 1.8 A | Fuse: 3 A, 250 V, |
| ||
consumption |
|
| mm |
|
|
|
|
|
|
|
|
Maximum power | 161 W |
|
|
| |
consumption |
|
|
|
|
|
|
|
|
|
|
|
Heat dissipation | 550 BTU/h |
|
|
| |
|
|
|
|
| |
Table |
|
|
| ||
|
|
|
|
|
|
|
| Requirement |
|
|
|
|
|
|
|
|
|
Parameter |
| Minimum |
| Maximum |
|
|
|
|
|
|
|
Temperature: |
|
|
|
|
|
Operating |
| 41°F (5°C) |
| 104°F (40°C) |
|
Nonoperating |
|
| 140°F (60°C) |
| |
|
|
|
|
|
|
Altitude: |
|
|
|
|
|
Operating |
| Sea level |
| 15,000 ft. (4,572 m) |
|
Nonoperating |
| Sea level |
| 40,000 ft. (12,191 m) |
|
|
|
|
|
|
|
Relative humidity: |
|
|
|
|
|
Operating |
| 20% noncondensing | 80% noncondensing |
| |
Nonoperating |
| 10% noncondensing | 90% noncondensing |
| |
|
|
|
|
|
|
The server power supply has overcurrent protection on the +5 V output and overvoltage protection on +5 V DC. The server’s total power consumption is approximately 161 W maximum.