Changing the Configuration

4-3

Changing the

To change the communications server configuration, follow this

Configuration

procedure:

 

1 Enter the firmware configuration command fc at the monitor prompt.

 

The following menu is displayed:

Firmware Configuration Utility

Commands:

C- Change parameters

D- Display parameters es - Exit to monitor

c

2Type D to display current parameter settings.

The following display shows factory default settings for the CS/2600 (except for Ethernet address, which is only an example):

 

 

 

Current

Parameters:

 

Ethernet address

080002025DAC

 

Console

baud

rate

9600

 

Console

port

 

0

 

Continuous self-test

Disabled

 

Auto-reboot

 

Reboot only

 

Monitor

 

 

Disabled

 

Initial

boot

source

Floppy then

Network

Number

of reboots

00

 

Network

boot

string

_cs200

 

Boot

retries

 

Try Forever

 

Boot

protocol

 

SLP

 

Number

of ports

10

 

Default

memory map

CS/2500/2600

 

RS-232

ports

 

0 1 2 3 4 5

6 7 8 9

RS-422

ports

 

 

 

Auto RS-422 select

Disabled

 

LF issued after CR

YES

 

Printer

setup

string:

 

 

Default settngs for the CS/2500 are the same, except that Initial Boot

Source is “Network.”

3To return to the Firmware Configuration Utility menu, press the Return key.

Page 51
Image 51
3Com CS/2500 manual Changing, Procedure, Following menu is displayed